Wireless sensor solutions for pharmaceuticals manufacturing. Avoid lost batches with continuous monitoring of critical equipment. Gain insight into key manufacturing processes. Get real-time feedback and alerts via phone, text, or email. Part of the Leap Sensors system for the Industrial IoT.
-
The Pressurized Dew Point (PDP) wireless sensor monitors the dew point temperature inside compressed air lines. Because water condenses at a higher temperature when the air is pressurized, the sensor sends an alert when the temperature inside the air lines is nearing the dew point. This provides the plant maintenance team ample warning to take action to head off major equipment malfunctions and damage. This Leap sensor integrates the Michell Easidew EA2 Moisture Meter. Part of the breakthrough Leap Sensors® system. Build your quote here:
-
The Leap wireless pressure transceiver can integrate with every type of sensor with a 0 - 10 V output. The sensor is powered by the Leap Sensor device battery with a power supply that can be specified from 0 to 24 volts. No external power source is needed.Contact us to let us help you make your selected 0 - 10 V sensor wireless. Part of the breakthrough Leap Sensors® system. Build your quote here:
-
The Leap wireless pressure transceiver can integrate with every type of sensor with a 0 - 5 V output. The sensor is powered by the Leap Sensor device battery with a power supply that can be specified from 0 to 24 volts. No external power source is needed.Contact us to let us help you make your selected 0 - 5 V sensor wireless. Part of the breakthrough Leap Sensors® system. Build your quote here:
-
The Leap wireless 4-20 mA transceiver node can integrate with every type of sensor with a 4-20mA output.
Configured to Your Exact Application
The external industrial sensor may be powered by an optional 12 or 24V power supply driven from the over-sized Leap Sensor node battery. No external power source is needed with the 12/24V power supply option (LP-1PXX). See below for other options to configure this industrial wireless sensor node to your exact needs. Contact us to let us help you make your selected 4-20 mA sensor wireless. Part of the breakthrough Leap Sensors® system. Build your quote here: -
This Leap Sensor comes with a fast-to-install split-core AC amp clamp to sense the AC electrical current going to equipment. Amp clamps are a powerful industrial tool to monitor power usage and to monitor equipment for conditions that predict impending failures. A change in AC current to industrial equipment can be an early indication to plan downtime to prevent failures during production. A wide range of amp clamps can be integrated with the Leap system. Contact us with your specific needs.Price for 0-50A AC RMS current transformer. Contact us for pricing on other current transformer options.Contact Us
Prices, Quotes, Questions...
Need a price or a quote? Have questions? Want to talk to an expert? Need a custom solution?Contact Us -
The Leap wireless transceiver can integrate with most sensors with a CAN bus interface. The sensor is powered by the Leap Sensor device battery with a power supply that can be specified from 3.6V to 24 volts. No external power source is needed. Contact us to let us help you make your selected CAN bus sensor wireless. Contact us with the details of the CAN sensor that you want to integrate with the Leap wireless sensor system. Build your quote here:Part of the breakthrough Leap Sensors® system.
-
This very unique wireless sensor works by comparing the readings from one device node to another user-selected device node - then reporting the local pressure, local temperature - then differential pressure and temperature as compared to a user selected sensor. For example, sensor A is located outside at ambient temperature and pressure. Sensor B is located in a clean room under positive pressure and Sensor C is located in a different part of the cleanroom under a higher positive pressure. Sensor B could be configured to report its pressure and temperature and the differential pressure between Sensor B and Sensor A. (See the screen shot). Sensor C could be configured to report its pressure and temperature and the differential pressure and temperature between sensor C and sensor B. Sensor readings are reported in PSIA. Leverage the Leap SensorManager software to send text, email, or telephone alerts when a pressure, temperature, or delta-pressure or delta-temperature threshold is exceeded. Integrate the data from the differential pressure sensors into other software using our web-based API, Modbus, DNP3, or other data interface protocols. The wireless sensor can be configured with pressure sensors that have different ranges, resolutions, and accuracies for different applications. See the specification below for more information on the different options. Pressure sensors can be configured to specific applications. The pressure and temperature sensors in the photos have the pressure and temperature sensor sealed inside the enclosure with a pressure port in the back of the enclosure.Part of the breakthrough Leap Sensors® system. Build your quote here: