Shop

Contact an Expert 1-866-608-6168

  • The Pressurized Dew Point (PDP) wireless sensor monitors the dew point temperature inside compressed air lines. Because water condenses at a higher temperature when the air is pressurized, the sensor sends an alert when the temperature inside the air lines is nearing the dew point. This provides the plant maintenance team ample warning to take action to head off major equipment malfunctions and damage. This Leap sensor integrates the Michell Easidew EA2 Moisture Meter.     Part of the breakthrough Leap Sensors® system.   Build your quote here:
  • This wireless temperature sensor employs a heavy-duty 4-inch metal probe. Ideal for remote monitoring of heating and cooling temperatures during meat & poultry processing.
    • Rugged probe: 3/16″ diameter needle that reduces to 0.15″ at the tip.
    • Wide temperature range: from -40 to 500 degrees Fahrenheit.
    • Rapid response time of 5 seconds in liquid.
    • Data logging makes tracking & storing internal meat temperature to streamline USDA Appendix A & B compliance.
    Wide variety of probes available. Contact us to learn about options for your specific applications.   Part of the breakthrough Leap Sensors® system.   Build your quote here:
  • This wireless sensor node replaces the discontinued Synapsense wireless temperature sensor module.  The Leap sensor node has a connector that connects to existing Snapsense temperature sensor wiring harnesses. A Leap wireless gateway and Leap software are required.  Data may be passed to other software using the web-API or Modubs. Convert your discontinued Synapsense monitoring system to the latest technology.   Part of the breakthrough Leap Sensors® system.
  • This highly versatile industrial sensor supports 6 to 9 miniature, low-mass precision RTD temperature sensors connected to a transceiver node in an industrial enclosure. Ideal for data center rack remote monitoring.
    Contact Us

    Questions, Quotes?

    Need pricing or a quote? Have questions? Talk to our experts.
    Contact Us
    • 3-wire RTD connection supports long cables while also maintaining high temperature accuracy.
    • Readings as fast as every 3 seconds for each of the sensors.
    • Data logging capability when the transceiver node is not linked to a gateway.
    • Option to integrate existing rack monitoring probes for "plug & play" installation.
    Part of the breakthrough Leap Sensors® system.
  • This wireless sensor communicates via a cellular transmission for remote temperature & flood monitoring.  The internal antenna keeps the transceiver node small and resistant to damage. Sensor transceiver node combines standard mini k-type thermocouple connector for temperature sensing (wide temperature range) and a water sensor for flood detection. No gateway required – ideal for remote locations where standard sensors won’t work. Sensor node transmits via cellular link directly to cloud-based user interface. Receive alerts by email or text. “Practically battery-free”™ - Long battery life (up to 10 years, depending on application & transmission interval). Customize to your specific needs, including options to transmit only when designated thresholds are exceeded.     Part of the breakthrough Leap Sensors system.   Build your quote here:
  • This optional current transformer can be connected to the wireless Motor Monitor Transceiver Node to detect a rise in current that in indicative of a failing machine. Designed specifically for use in a machine condition based monitoring system as part of a condition based maintenance program.   Part of the breakthrough Leap Sensors® system for the IIoT. Price is for a 0-50A AC split core current transformer.  Please let us know if you need a current transformer with a higher rating.   Build your quote here:
  • This vibration and temperature module connects over the CAN bus to the Wireless Motor Monitor transceiver node and send temperature and vibration data.   Part of the breakthrough Leap Sensors® system for the IIoT.   Build your quote here:
  • Coming Soon

    This Leap wireless sensor has eight standard mini thermocouple connectors that can connect to any type of thermocouple (type K is standard). Because thermocouples can be used over a wide temperature range and thermocouples come in a huge range of probe types, this sensor addresses many harsh industrial applications.  
    Contact Us

    Prices, Quotes, Questions...

    Need a price or a quote? Have questions? Want to talk to an expert? Need a custom solution?
    Contact Us
  • Put all of your most important sensor data and graphs on one page with the Dashboard option in the Leap software. Dashboards can be configured for you by the Phase IV Engineering team - or select the option to configure your own dashboards.  
    Contact Us

    Prices, Quotes, Questions...

    Need a price or a quote? Have questions? Want to talk to an expert? Need a custom solution?
    Contact Us
    Contact us for pricing on your specific requirements.
  • This Leap wireless transceiver node integrates two standard industrial pressure sensors along with two thermocouples. (Type K is standard, but other types can also be integrated). The sensor is powered by the Leap Sensor device battery with a power supply that can be specified - 12 or 24 volts. No external power source is needed.   Contact us to let us help you make your selected pressure sensors and thermocouples wireless. Part of the breakthrough Leap Sensors® system.   Build your quote here: Contact us for pricing for your unique configuration.
  • Wireless transceiver node designed to integrate with any ring force transducer that has one of these outputs: mV/V, 4-20 mA, or 0-10V.  The Leap transceiver node provides power to the ring force transducer. Ideal for monitoring preloads, testing equipment, clamping forces, and remote ongoing force and load monitoring. Contact us to find the best ring force transducer configuration for your specific application.       Part of the breakthrough Leap Sensors® system.   Build your quote here:
  • Breakthrough technology uses CAN bus to "daisy chain" multiple load cell interface modules to one wireless Leap transceiver node. Anywhere from 2 to 30 load cell modules can be added to the bus. Each load cell module can support 2 full-bridge mV/V load cells, for a total of up to 60 load cells per transceiver node. Edge processing at the strain sensor level assures a high-quality conversion of the sensor voltage reading to a digital reading, which can then be reliably sent via the CAN bus to the wireless transceiver node. Industrial CAN bus cables can be over 600 feet long. Ideal for wireless monitoring loads and force in several places along structural components such as I-beams, girders, support columns, etc. Contact us to find the best strain sensor configuration for your specific application. Part of the breakthrough Leap Sensors® system. Contact us for pricing on your specific configuration. Build your quote here:
Go to Top